5.5 Regulation of primary air
Referred to distance “A” in mm.
60 cm hobs with separable control panel.
90 cm hobs with separable control panel.
60 cm hob with built-in control panel.
To identify the burners on your hob, refer to the drawings in point
“6.3/6.4 Arrangement of burners on hob”
15
Burner NG - 1.0 kPa ULPG - 2.75 kPa
Auxiliary (1) 3.0 2.0
Semirapid r (2) 2.5 4.0
Semirapid l (3) 2.5 4.0
Rapid large (4) 2.0 5.0
Wok (5) 7.0 4.0
Burner NG - 1.0 kPa ULPG - 2.75 kPa
Auxiliary (1) 6.0 6.0
Semirapid (2) 3.0 8.0
Rapid (3) 5.0 12
Fish burner (4) 5.0 12.0
Wok (5) 4.0 11.0
Burner NG - 1.0 kPa ULPG - 2.75 kPa
Auxiliary (1) 3.0 2.0
Semirapid r (2) 2.5 4.0
Semirapid l (3) 2.5 4.0
Rapid medio (4) 2.0 5.0
Wok (5) 7.0 4.0