INSTALLATION OF INDOOR & OUTDOOR UNIT
Read completely, then follow step by step.
Capacity is based on standard length and maximum
allowance length is on the basis of reliability.
Oil trap should be installed every 5~7 meters.
In case more than 5m
A
Indoor unit
Oil trap
Outdoor unit
A
Indoor unit
Outdoor unit
A
Do not have any heat or steam near the
unit.
Select a place where there are no
obstacles in front of the unit.
Make sure that condensation drainage
can be conveniently routed away.
Do not install near a doorway.
Ensure that the space around the left and
right of the unit is more than 100mm. The
unit should be installed as high on the
wall as possible, allowing a minimum of
200mm from ceiling.
Use a stud finder to locate studs to
prevent unnecessary damage to the wall.
More than 100mm
More than 200mm
More than 2300mm
More than 100mm
Install the indoor unit on the wall where the height
from the floors more than 2300 mm.
B
If an awning is built over the unit to
prevent direct sunlight or rain exposure,
make sure that heat radiation from the
condenser is not restricted.
Ensure that the space around the back
and sides is more than 300mm. The front of
the unit should have more than 700mm of
space.
Do not place animals and plants in the
path of the warm air.
Take the air conditioner weight into
account and select a place where noise
and vibration are minimum.
Select a place so that the warm air and
noise from the air conditioner do not
disturb neighbors.
Select the best location
Indoor Unit
CAUTION
Outdoor Unit
If the outdoor unit is installed on a roof structure, be
sure to level the unit. Ensure the roof structure and
anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
Rooftop Installation
Piping length and elevation
CAUTION
INSTALLATION
8
B
Capacity
(Btu/h)
18K (5 star)
24K Cooling
24K
Cooling & Heat Pump
5/8" 3/8"
3 to 5
Pipe Size
GAS LIQUID
Standard
Length
(m)
1/2" 1/4"
1/4"
3 to 5
3 to 5
20
20
20
20
5/8" 1/4" 3 to 5 20 30
20 30
Max.
length
(m)
A
Additional
Refrigerant
(g/m)
9K 3/8"
9K, 12K,
18K (2,3 star)
18K Heat Pump