Dimension
Capacity
A B C D E F G H I
102K BTU/h
(LB-H0852QC)
1625 1564 597 65 660 294 1220 30430
18
B
e
n
z
e
n
e
S
C
O
U
R
I
N
G
C
L
B
A
R
G
E
R
S
I
N
N
E
R
Air outlet vent
Air outlet vent
Air filters
Care and maintenance
Care and
maintenance
Indoor Unit
Caution: Before performing any maintenance, turn off the main power to the system.
Grille, Case, and Remote Control
qTurn the system off before cleaning. To clean,
wipe with a soft, dry cloth. Do not use bleach or
abrasives.
Note:
Supply power must be disconnected before
cleaning the indoor unit.
q
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or
discoloration.
• Volatile substances
Could damage the surfaces
of the air conditioner.
Clean the filter with a vacuum or warm, soapy
water.
If very dirty, wash with a solution of
detergent in lukewarm water.
If hot water (50°C or more) is used, filter
may be deformed.
After washing with water, dry well in the shade.
Re-install the air filter.
Air Filter
The air filters behind Indoor unit
(the suction side) should be checked and cleaned
once every 2 weeks or more often if necessary.
1
2
3
Slope 5-8 mm
Indoor Unit Dimensions (mm)
Slope of about 5-8 mm is to be provided at the
drain hole side of the indoor unit for proper
drainage.
• After installation the slope can be measured
using a sprit level.
90K BTU/h
(LB-H0750QC)
1625 1564 597 65 660 294 1220 30430