INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
TYPE : (For High Temperature)
Hydro Kit
P/NO : MFL67212806
http://www.lghvac.com
www.lg.com
ENGLISH
FRANÇAIS
ESPAÑOL
Vista de pagina 0
1 2 3 4 5 6 ... 50 51

Indice de contenidos

Pagina 1 - AIR CONDITIONER

INSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Installation work must be perform

Pagina 2 - TABLE OF CONTENTS

Installation10Hydro KitFoundation for Installation• Fix the unit tightly with bolts as shown below so that the unit will not fall down due to earthqua

Pagina 3 - 1. Safety Precautions

Installation ENGLISHHydro Kit Installation Manual 11General ConsiderationsFollowings should be considered before beginning water circuit connection

Pagina 4 - ■ Operation

Installation12Hydro KitOn-site installation (1)Hydro kit(For High Temperature)Union joint (2) Thermometer (6) Excessive pressure safety valve(10)Press

Pagina 5 - ■ Installation

Installation ENGLISHHydro Kit Installation Manual 13* Water tank & Floor heating installation1. Use the pump (1) with sufficient capacity to as

Pagina 6 - 2. Installation Parts

Installation14Hydro KitStrainer- Use the 50 mesh strainer. (Exclude scale diameter of 0.4mm or less and other net)- Check the strainer direction and a

Pagina 7 - Model Information

Installation ENGLISHHydro Kit Installation Manual 15Installation ConditionInstalling Domestic Hot Water tank requires following considerations :• D

Pagina 8 - Line supporter

Installation16Hydro KitInstallation ScenesSome installation scenes are presented for example. As these scenes are conceptual figures,installer should

Pagina 9 - Installation Space

Installation ENGLISHHydro Kit Installation Manual 17Water QualityWater quality should comply with EN 98/83 EC Directives. Requirement for resolved

Pagina 10 - Foundation for Installation

Installation18Hydro KitCut the pipes- Use the accessory piping kit or the pipespurchased locally.- Measure the distance between the indoorand the outd

Pagina 11 - General Considerations

Installation ENGLISHHydro Kit Installation Manual 19Precaution when connecting Heat Recovery systemsPipe searching process1. When pipe searching pr

Pagina 12 - Water cycle

Hydro KitInstallation ManualTABLE OF CONTENTS1. Safety Precautions...

Pagina 13 - Installation of floor heating

Installation20Hydro KitConnect the wires to the terminals on the control board individually according to the outdoor unitconnection.*Ensure that the w

Pagina 14 - Strainer

Installation ENGLISHHydro Kit Installation Manual 21Connecting CablesTypes of the cablesThe distance between communication cable and power cable- I

Pagina 15 - Installation Condition

Accessories Installation22Hydro KitLocation of Accessories and External Parts ConnectionDry contact board socket. (CN-CC)Dry contact board attachment

Pagina 16 - Installation Scenes

Accessories InstallationENGLISHHydro Kit Installation Manual 2322133<Wire guide grooves>WallSideWallSideWallSideWallSide<Connecting order>

Pagina 17 - Frost protection

Accessories Installation24Hydro Kit4. Please connect indoor unit and remote controller using connection cable.5. Please use extension cable if the dis

Pagina 18 - Refrigerant Piping

Accessories InstallationENGLISHHydro Kit Installation Manual 25Water tank temperature sensor Connection• Select the suitable pump by referring to the

Pagina 19 - Pipe searching process

Accessories Installation26Hydro KitInstallation ConditionThermostatThermostat is generally used to control the unit by air temperature. When thermosta

Pagina 20 - How to connect wirings

Accessories InstallationENGLISHHydro Kit Installation Manual 27General InformationHydro Kitsupports following thermostats.(1) There is no electric ci

Pagina 21 - Connecting Cables

Accessories Installation28Hydro KitRemote Temperature SensorRemote temperature sensor can be installed any place a user wants to detect the temperatur

Pagina 22 - 5. Accessories Installation

Accessories InstallationENGLISHHydro Kit Installation Manual 29WARNING : • 3way valve should select water tank loop when electric power issupplied to

Pagina 23 - <Separating order>

Do not modify or extend thepower cable.• There is risk of fire or electricshock.Do not install, remove, orreinstall the unit by yourself(customer).• T

Pagina 24 - Hydro Kit

Accessories Installation30Hydro KitLG Dry Contact is a solution for automatic control of HVAC system at the owner's best. In simple words, it&apo

Pagina 25 - Water tank

System Set-UpENGLISHHydro Kit Installation Manual 31As Hydro Kit(For High Temperature) is designed to satisfy various installation environment, it is

Pagina 26 - Thermostat

System Set-Up32Hydro KitGroup Control SettingGroup Control- Wired remote controller 1 + Many of Hydro Kit- Dip Switch in PCB 1. It is possible to conn

Pagina 27 - Hydro Kit

System Set-Up ENGLISHHydro Kit Installation Manual 335. In case that the indoor unit has an abnormal problem an error code will be displayed on

Pagina 28 - Remote Temperature Sensor

System Set-Up 34Hydro KitEmergency Operation• Definition of terms- Trouble : a problem which can stop system operation, and can be resumed temporall

Pagina 29 - 3Way Valve

System Set-Up ENGLISHHydro Kit Installation Manual 35• Following features are permitted in emergency operation :- Operation On/Off- VIEW TEMP b

Pagina 30 - Dry Contact

System Set-Up 36Hydro KitInstaller SettingHow to enter installer setting modeCAUTION Installer setting mode is to set the detail function of the rem

Pagina 31 - DIP Switch Setting

System Set-Up ENGLISHHydro Kit Installation Manual 37SummaryExample of Fuction Code DisplayFunction Code Value #1 Value #2Function Default Value

Pagina 32 - Group Control Setting

System Set-Up 38Hydro KitCommon Setting• Function Code 02 : Disable 3 minute DelayOnly used for an inspection in a factory.• Function Code 03 : Remo

Pagina 33 - CAUTION

System Set-Up ENGLISHHydro Kit Installation Manual 39Temperature Range Setting• Function Code 13 : Setting Air Temperature in Heating ModeDeterm

Pagina 34 - System Set-Up

Safety Precautions OperationTake care to ensure thatpower cable could not bepulled out or damaged dur-ing operation.• There is risk of fire or electr

Pagina 35

System Set-Up 40Hydro KitTemperature Control Parameter Setting and Etc• Function Code 23, 24, and 25 : Setting Weather-dependent operationWeather-de

Pagina 36 - Installer Setting

System Set-Up ENGLISHHydro Kit Installation Manual 41• Function Code 26 and 27 : Setting Disinfection operationDisinfection operation is special

Pagina 37

System Set-Up 42Hydro Kit• Function Code 28 and 29 : Setting control parameter for Sanity water heating operationDescriptions for each parameters ar

Pagina 38 - Common Setting

System Set-Up ENGLISHHydro Kit Installation Manual 43• Function Code 2B : Setting Domestic Hot Water heating timersDetermine time duration : Ope

Pagina 39 - Temperature Range Setting

System Set-Up 44Hydro KitWARNING : When Hydro Kit is used with the DHW tank, it is STRONGLY recommended to install recirculationpump to prevent cold

Pagina 40

System Set-Up ENGLISHHydro Kit Installation Manual 45Installing Thermostat• DIP switch setting : Set DIP switch No. 8 to ‘ON’. Otherwise, the un

Pagina 41 - WARNING

System Set-Up 46Hydro KitSequence of thermostat operation- How to set the heating temperature when thermostat is connected to the Hydro Kit.Set ther

Pagina 42

ENGLISHHydro Kit Installation Manual 47Test Run• Check whether water flow is smoothly supplied.• Check whether the flow switch properly operates.• Ch

Pagina 43 - 2B.01 2B.012B.02 2B.022B.02

48Hydro KitTest Run • This function displays the disorder types at the self diagnostics and the occurrence of the dis-order for the product.• The di

Pagina 44 - Installing recirculation pump

ENGLISHHydro Kit Installation Manual 49Test RunInverter PCB error display methodRed LED means error number 10 digits, and green LEDmeans 1 digit, and

Pagina 45 - Installing Thermostat

Turn the main power offwhen cleaning or maintain-ing the unit.• There is risk of electric shock.Take care to ensure thatnobody could step on or fallon

Pagina 47 - Caution before Operation Test

US1. Please call the installing contractor of your product, as warranty service will be provided by them.2. If you have service issues that have not b

Pagina 48 - Troubleshooting

Installation Parts6Hydro Kit2. Installation PartsThank you for choosing LG Electronics Hydro Kit.Before starting installation, please make it sure tha

Pagina 49 - Green LED: 1 digit

General Information Model InformationWith advanced inverter technology, Hydro Kit is suitable for applications like under floor heat-ing, and hot wa

Pagina 50

8Hydro KitInstallationTransporting the Unit• When carrying the suspended unit, pass the ropes between legs of base panel under the unit.• Always lift

Pagina 51

Installation ENGLISHHydro Kit Installation Manual 91. Select space for installing the unit, which will meet the following conditions:• The place wh