System Set-Up
ENGLISH
Hydro Kit Installation Manual 43
• Function Code 2B : Setting Domestic Hot Water heating timers
Determine time duration : Operation time and stop time of Domestic Hot Water tank heating.
- Value #1 of Function Code 2B : This time duration defines how long Domestic Hot Water
tank heating can be continued.
- Value #2 of Function Code 2B : This time duration defines how long Domestic Hot Water
tank heating can be stopped. It is also regarded as time gap
between Domestic Hot Water tank heating cycle.
- Example of timing chart :
• Function Code 2E and 2F : Changing thermal on/off temperature
Select Thermal on/off Temperature gap.
• Function Code 30 : Remote Controller Program Version
Display Remote Controller Program Version.
Th On Th Off
0
-0.5°C (-0.9°F) 1.5°C (2.7°F)
1
4°C (7.2°F) 6°C (10.8°F)
2
2°C (3.6°F) 4°C (7.2°F)
3
-1°C (-1.8°F) 1°C (1.8°F)
2E : Room Air temperature
Th On Th Off
0
-2°C (-3.6°F) 2°C (3.6°F)
1
-6°C (-10.8°F) 4°C (7.2°F)
2
-2°C (-3.6°F) 4°C (7.2°F)
3
-1°C (-1.8°F) 1°C (1.8°F)
2F : Leaving Water temperature